Herunterladen Diese Seite drucken

Ibiza LEDBAR24-RC Bedienungsanleitung Seite 3

Rgbw ledbar 4-in-1

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
MANUAL - LED-LEDBAR24-RC
SETUP
Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
FUSE REPLACEMENT
With a flat head screwdriver wedge the fuse holder out of its housing.
Remove the damaged fuse from its holder and replace with exactly the same type of fuse.
Insert the fuse holder back in its place and reconnect power.
The fuse is located inside this compartment. Remove using a flat head screwdriver.
FIXTURE LINKING
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can
support.
Important: Fixtures on a serial/data link must be daisy chained in one single line. Maximum recommended
serial data link distance: 100 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link:
32 fixtures
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX CONNECTOR CONFIGURATION
Termination reduces signal errors. To avoid signal
transmission problems and interference, it is always
advisable to connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the fixture's chassis ground. Grounding the common can cause
a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to check correct polarity
and to make sure the pins are not grounded or shorted to the shield or each other.
SETTING UP A DMX SERIAL DATA LINK
1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the
controller.
2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the
input connector of the next fixture consisting of a (male) 3 pin connector.
3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on.
MASTER/SLAVE FIXTURE LINKING
1. Connect the (male) 3 pin connector of the DMX cable to the output (female) 3 pin connector of the first
fixture.
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the
input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the
output as stated above to the input of the following fixture and so on
3. Often, the set up for Master-Slave and Stand-alone operation requires that the first fixture in the chain be
initialized for this purpose via either settings in the control panel or DIP-switches. Secondarily, the fixtures that
follow may also require a slave setting. Please consult the '' Operating Instructions» section in this manual for
complete instructions for this type of setup and configuration.
HOW TO CONTROL THE UNIT
Access control panel functions using the four panel buttons located directly underneath the LCD Display.
Button
Function
MENU
Used to access the menu or to return to a previous menu option
UP
Scrolls through menu options in ascending order
DOWN
Scrolls through menu options in descending order
ENTER
Used to select and store the current menu or option within a menu
COMMON
DMX +
INPUT
DMX-
ibizashop.eu
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3
(DMX+) of the last
fixture.
8.8.8.8.
MENU
UP
DOWN
ENTER
EN
3

Werbung

loading