Herunterladen Diese Seite drucken

WilTec ATP Serie Bedienungsanleitung Seite 16

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The user is responsible for the compliance with location specific safety and installing regula-
tions. (Ask an electrician).
Consequential damage arising from flooded rooms caused by dysfunctions of the appliance
must be avoided by means of the appropriate measures. (installing an alarm system, reserve
pump).
In case of malfunction the repair work can be carried out only by a qualified electricial or the
WilTec-service.
The appliance must not run dry or with a completely closed intake port. The manufacturer's
guarantee is no longer valid if the damage is caused by dry running.
The appliance must not be used for swimming pools.
The device cannot be employed for potable water circuits.
WARNING:
Read carefully all the safety guidelines and the instructions.
Non-compliance with the safety rules and regulations can lead to an electric shock, fire and/or serious
injury. Keep the instructions and the safety guidelines in a safe place in case you need them in the
future.
Stability
The max. temperature of the conveyed liquid should not exceed +35°C in permanent operation.
The conveyance of aggressive fluids (acids, bases, etc.) as well as of abrasive substances (for exam-
ple sand) must be avoided.
Electrical connection
The electrical connection takes place via an electric safety socket 230 V ~ 50 Hz. Fuse protection
at least 10 Amperes.
The appliance is turned on/off by means of the ON-/OFF-switch. The indicator light of the switch
glows, if the engine is started.
The engine is protected against overloading or blocking by means of a built-in motor protection. In
case of overheating the pump is turned off automatically due to the overheat protection and after
the cooling the pump is automatically started.
Power connection
The pond pump is equipped with a safety plug. The device is designed for connection to an isolated
ground receptacle with 230 V~50 Hz. Make sure that the socket outlet is sufficiently fused (at least 6A)
and safe. Insert the plug in the socket outlet and the pond pump is ready for use.
Note:
Installation
The pump is to be installed as follows: in a fixed position with fixed or flexible hose.
Utilisation as submersed pump (see picture 1)
Immerse the pump into the pond water, so that it is filled with water.
To avoid the premature clogging of the filter, position the pump above the pond sludge.
Install the supplied filter sponge to keep the pump inlet free.
The pump is started by plugging in the mains plug.
© by WilTec Wildanger Technik GmbH