maintenance. Please ensure that when cell replacement is necessary you use the
correct genuine Eco Salt® replacement cell to match your system. The correct Eco
Salt® Replacement cells to use are BMSC13, BMSC20 and BMSC26 to match the
Model Chlorinator you have.
BMSC SYSTEMS Please Note that unless you have extreme water conditions the Cell
should not become scaled and you should not have to clean the Cell. In areas of
extremely hard water it may be necessary to clean your cell periodically. Refer Below.
To clean the BMSC Cell
it should be disconnected from the Power Supply Unit and
removed from the pool return line by undoing the unions. Take care not to lose the o-
rings and always make sure that the Power Supply is turned off – failure to do so may
result in the pool pump turning on while the Cell is not in place.
METHOD 1
Add 1 part HYDROCHLORIC ACID to 5 parts WATER in a suitable container. The Cell
should be placed on a surface that allows it to form a U shape and some of the solution
can be poured into the up-turned cell. Take care when doing this as the solution can
foam and create a spill which must be cleaned up by dilution. As an alternative the Cell
can be immersed completely in a container. When clean the Cell should be rinsed
thoroughly and the connection should be dried carefully to avoid connector corrosion. It
should not take longer than a few minutes to clean, if it does the Cell should be cleaned
more frequently. Return the Cell to its position and re-connect it.
METHOD 2
As an alternative, an approved commercial Cell cleaning solution can be used a number
of times effectively.

SAFETY DEVICE:

Hydrogen Gas is a by – product of the chlorine producing process. A Gas Sensor has
been incorporated into the Unit and Cell, which will switch off chlorination if gas is
detected in the Cell Housing or there is no water flow.
Eco Salt® Units are also fitted with a Thermal Cut – Out to prevent overheating. If the
temperature rises too high, power is automatically disconnected. The Unit will resume
operation when it cools down.