Herunterladen Diese Seite drucken

Grundig GIEH 834480 P Installationsanleitung Seite 20

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
Make sure that the furniture is in straight,
horizontal position and that it is fixed
before the installation of the appliance.
Do not install heat insulation strips to
the furniture that the appliance shall be
installed.
The air to be expelled from the product
should not be fed into a chimney used
by other appliances burning gas or other
fuels. (not applicable for appliances that
discharge air back into the room).
Legislation regarding the evacuation of
air must be complied with.
Poisoning Danger! While the appliance
is operating, air is drawn from the whole
house. If adequate ventilation is not
provided, air flow occurs and the waste
and toxic gases released as a result of
combustion in the house are reabsorbed.
Do not operate the product together with
products that provide air circulation and
may emit toxic gas (wood, gas, oil and
coal stoves, boilers, water heaters, etc.).
Have the adequacy of your building' s
ventilation and chimney system checked
by authorized persons.
If there is another appliance operating
with energy other than electrical energy
in the same environment with ventilation,
the negative pressure in the room should
be at most 0.04 mbar so that the exhaust
of the other appliance is not drawn back
into the room by the ventilation.
Dimensions given in installation diagrams
are in mm.
Legislation regarding the evacuation of
air must be complied with.
Oil sludges may form on metal oil filters.
For that reason, there should not be
any flame near the product. In addition,
installation of the product near a heating
equipment using solid fuel is only
permitted if there is a non-removable
closed cover to prevent sparks.
Our company shall not be responsible for
problems that arise for not observing any
of the warnings above.
The product manufacturer does not
accept any responsibility for the defects
caused by the ventilation pipes used in
the installation.
The air outlet pipe to be used should be
as short as possible, straight and should
have a large diameter.
20
Long air outlet pipes, multiple pipe bends
or small pipe diameters reduce ventilation
performance and increase fan noise.
The air outlet pipe must be made of non-
combustible material.
The air outlet pipe should be installed
with an inclination of 1 degree to prevent
the return of condensation.
Product dimensions (Figure 1)
Pay attention to the product dimensions.
Consider its suitability with your furniture.
Your product is suitable for 3 different types
of installation according to the suitability of
your furniture. A, B and C type installations are
described respectively.
A : Installation without internal circulation shaft
B : Installation with internal circulation shaft
C : Installation with external circulation
A type installation (Installation
without internal circulation
shaft)
Preparation of the furniture on which
installation will be made: (Figure A2)
Prepare your furniture according to the
dimensions presented in Figure A2. Cut
dimensions for flush-fit installation are also
indicated in Figure A2.
Steps for A type installation
Remove the tape on the countertop
plastic described in Figure A3, and place
it in its slot on the back of the hob as
shown in the figure.
Completely remove the drawers of your
furniture and place your stove in its place
on your furniture. (Figure A4)
Stick the countertop plastic on the wall
by pulling it towards the wall through the
gap you have opened in your furniture.
(Figure A5)
Put your drawers back in place. (Figure
A6)
Remove the metal oil filter by pulling it
upwards. (Figure A7)
Remove the liquid collection chamber as
shown in the figure A7.
Place two units of active carbon filters to
right and left as shown in figure A8.
Place back the liquid collection chamber
as shown in the figure A9. Complete the
installation by placing back the metal oil
filter.

Werbung