WARRANTY TERMS
For information concerning warranty terms, visit our website at: www.bestwaycorp.com.
TROUBLESHOOTING
Problems
• The running time of the product is
• The salt concentration is not
• The electrolytic cell is blocked or
Insufficient chlorine
concentration
• Increase in swimmers.
• Strong exposure to the sun leads
Flocculent
There is too much calcium in the
precipitation in water
pool water.
LED indicator has
• Not plugged in.
no display code
• The LED indicator fails.
ERROR CODES
Problems
No water flow.
The water flow is less than
280 gal/h (1050 L/h), the
circulation system is blocked.
Display code "E0"
The direction of the inlet and outlet is
reversed.
Dirt in the water flow sensor.
The power cord of the water flow
sensor is loose.
Water flow sensor failure.
Dirt remains in the electrolytic cell.
Low salt concentration or no salt.
Display code "E1"
The electrolysis power cord is loose.
The electrolytic cell may fail.
Display code "E2"
Salt concentration is too high.
Display code "E3"
Electrolytic cell short circuit.
Probable Causes
not long enough.
enough (less than 2000 ppm).
left with dirt.
to the emission of chlorin
Probable Causes
• Please increase the running time of the product every day. For details,
please refer to "Operation Instructions".
• Adjust the salt concentration by referring to the "Pool Salt Table".
• If necessary, please disassemble the electrolytic cell for inspection and
cleaning. Please refer to "Maintenance".
• Please increase the running time of the product every day. When the
pool is not in use or the product is running, please cover the pool cover.
• Please increase the running time of the product every day. During the
running of the product, you can cover the surface of the pool and wait
2 days before using the test paper to test.
Empty about 20%-25% of the pool water volume, then add clean water to
reduce the hardness. If necessary, please disassemble the electrolytic cell
for inspection and cleaning.
• Plug in the power plug.
• Please contact Bestway Customer Service Center for replacement.
Make sure the filter is connected to the chlorinator and is running. See
"Installation Instructions"
If there is a water stop valve, make sure that the water stop valve is open.
Ensure that the filter element and the electrolytic cell are clean and free of
dirt or impurities. Exhaust the air from the entire circulation system. Please
refer to the filter manual.
Check the direction of the water inlet and outlet. If necessary, readjust the
water pipe. See "Installation Instructions".
Make sure the water flow sensor is clean (especially the rotor). Please
refer to "Maintenance".
Reconnect the water flow sensor firmly.
Please contact Bestway Customer Service Center for replacement.
If necessary, remove the electrode to check and clean it. Please refer to
"Maintenance".
Add salt. Please refer to "Pool Salt Table".
Make sure that the electrolytic cell line is firmly connected to the plug of
the electrolytic cell.
Please contact Bestway Customer Service Center for replacement.
Drain part of the pool water and add some clean water. Refer to "Salt and
Pool Water Consumption"
If necessary, remove the electrode to check and clean it. Please refer to
"Maintenance"