Seite 2
250mm/9.84in Fasteners are not included in the package! Remark: the hatched area always need to be supported by a flat planar mounting surface as minimum. Wider surface contact is recommended, smaller is not allowed! Rev D | 10-2023 www.schreder.com 2/11...
Seite 3
2 x M16 2 x M16 80±1Nm 80±1Nm 2 x M10 20±1Nm 2 x M10 2 x M10 20±1Nm 20±1Nm Do not exceed the proposed torque levels, as it may result in fraction of the parts! Rev D | 10-2023 www.schreder.com 3/11...
Seite 4
Tighten the clamp screws 4 x M16 4 x M16 4 x M16 80±1Nm 80±1Nm 80±1Nm 20±1Nm 20±1Nm 20±1Nm Do not exceed the proposed torque levels, as it may result in fraction of the parts! Rev D | 10-2023 www.schreder.com 4/11...
Seite 5
D - ALLOWED POSITIONING max 20mm Rev D | 10-2023 www.schreder.com 5/11...
Seite 6
For installations over 3m height: secondary safety system application is mandatory, which is appropriated for the luminaire load (e.g. safety cable). 2500mm/98.42in 2500mm/98.42in safety cable is supplied with the luminaire. Rev D | 10-2023 www.schreder.com 6/11...
Seite 7
Gear box Cable ID Connection Cable gland Suitable cable Ø Mains input Ø6-10mm or Ø10-14mm Mains re-launch Ø6-10mm or DC output to optical block M25/cable protection compatibility Ø10-14mm Dimming input Ø4.5-7.5mm or Ø7.5-10.5mm Dimming re-launch Rev D | 10-2023 www.schreder.com 7/11...
Seite 8
Recommended cable type Control signal PG16(Ø5-Ø7.5/Ø7.5-Ø10) H05RN-F, 2 x 1-1.5mm Connector ID Cable ID Line AC INPUT PG20(Ø6-Ø10/Ø10-Ø14) H07RN-F, 3 x 1.5-4mm Protective Earth H05RN-F, 5 x 1.0mm DC OUTPUT PG20(Ø6-Ø10/Ø10-Ø14) H07RN-F, 5 x 1.5mm Neutral Rev D | 10-2023 www.schreder.com 8/11...
Seite 9
At least 1 meter distance should be kept from surrounding walls, floor, and ceiling for all types of mounting/inclination. Maximum number of luminaires per MCB MCB B type Product Driver BRITELINE GEN2 2 @220V EUM-680MG/BG BRITELINE GEN2 2 @480V ESM-680MG/BG MCB C type Product...
Seite 10
J - ACCESSORIES - HOOD Hood can be ordered separately as an accessory. 12 x M4 Rev D | 10-2023 www.schreder.com 10/11...
Seite 11
.يف حاله الحاجه لتغري االسالك الداخليه , يتم ذلك من خالل الرشكه املصنعه او الوكيل املخول لعمل ذلك او شخص مخول لذلك RG 0 - Exempt .دامئا افصل الدائره الكهربائيه قبل تركيب او صيانه الجهاز No risk IEC/EN 62471 Exempt IEC/TR 62778, RG2-RG1,C 0.4m IEC/TR 62778, RG1-RG0,C 1.6m *worst case scenario Rev D | 10-2023 www.schreder.com 11/11...