ENG INSTALLATION INSTRUCTIONS
DEU INSTALLATIONSANLEITUNG
FRA INSTRUCTIONS DE MONTAGE
SRP UPUTSTVA ZA INSTALACIJU
25
5,6
PH2
A - PRODUCT OVERVIEW
EPA - Effective Projected Area
90°
45°
-10°
S1
Front
Rev D | 10-2023
ITA
ISTRUZIONI DI INSTALLAZIONE
POL INSTRUKCJE MONTAŻU
SPA INSTRUCCIONES DE INSTALACIÓN POR INSTRUÇÕES DE INSTALAÇÃO SWE INSTALLATIONSANVISNING
‫تعليامت الرتكيب‬
AR
blade dimensions
3.5 x 0.5 mm
A
BRITELINE GEN2 1 with Integrated driver
A
609mm
351mm
23.97in
NLD INSTALLATIE INSTRUCTIES
RUS Инструкции по установке
UL 1598
CSA C22.2
No. 250.0
4
5
6
B
C
436mm
13.81in
17.16in
S2
Top-down
www.schreder.com
BRITELINE
GEN2 1
Integrated version
DAN INSTALLATIONSVEJLEDNING
RON INSTRUCŢIUNI DE INSTALARE
4-8m
8-12m
600-700 W
12-15m
15m<
WEAR
PROTECTIVE
GLOVES
24
B
21.5kg
47.39lbs
Sideways
HUN TELEPÍTÉSI ÚTMUTATÓ
安装说明
CHI
UKR Інструкції з монтажу
120-277 V
IP
IK
277-480 V
10
66
50/60Hz
IP66
1/9

Werbung

loading

Inhaltszusammenfassung für Schreder BRITELINE GEN2 1

  • Seite 1 12-15m 50/60Hz No. 250.0 15m< WEAR PROTECTIVE GLOVES blade dimensions 3.5 x 0.5 mm A - PRODUCT OVERVIEW IP66 BRITELINE GEN2 1 with Integrated driver 609mm 351mm 436mm 21.5kg 23.97in 13.81in 17.16in 47.39lbs EPA - Effective Projected Area Top-down 90°...
  • Seite 2 250mm/9.84in 250mm/9.84in Fasteners are not included in the package! Remark: the hatched area always need to be supported by a flat planar mounting surface as minimum. Wider surface contact is recommended, smaller is not allowed! Rev D | 10-2023 www.schreder.com...
  • Seite 3 2 x M16 80±1Nm 2 x M16 80±1Nm 80±1Nm 2 x M10 2 x M10 20±1Nm 20±1Nm 2 x M10 20±1Nm Do not exceed the proposed torque levels, as it may result in fraction of the parts! Rev D | 10-2023 www.schreder.com...
  • Seite 4 D - ALLOWED POSITIONING Suspended installation max 90° max 90° 0° min -10° 0° min -10° Direct installation max 20mm Rev D | 10-2023 www.schreder.com...
  • Seite 5 (e.g. safety cable). 1500mm/59.05in safety cable is supplied with the luminaire. F - ELECTRICAL CONNECTION Remove the R-type buckles from the junction box R-type buckle Open junction box CONNECTION BOX Rev D | 10-2023 www.schreder.com...
  • Seite 6 Sealing for Ø10-Ø14 Sealing for Ø10-Ø14 Sealing for Ø10-Ø14 Cable gland shell Cable gland shell Cable gland shell Connection Cable gland Recommended cable type H05RN-F , 5 x 1.0mm AC INPUT PG20(Ø6-Ø10/Ø10-Ø14) H07RN-F , 5 x 1.5mm Rev D | 10-2023 www.schreder.com...
  • Seite 7 At least 1 meter distance should be kept from surrounding walls, floor, and ceiling for all types of mounting/inclination. Maximum number of luminaires per MCB MCB B type Product Driver BRITELINE GEN2 1 @220V EUM-680MG/BG BRITELINE GEN2 1 @480V ESM-680MG/BG MCB C type Product Driver BRITELINE GEN2 1 @220V EUM-680MG/BG...
  • Seite 8 The external aiming device position needs to be alig- ned with positions I - ACCESSORIES - HOOD Hood can be ordered separately as an accessory. 12 x M4 Rev D | 10-2023 www.schreder.com...
  • Seite 9 .‫يف حاله الحاجه لتغري االسالك الداخليه , يتم ذلك من خالل الرشكه املصنعه او الوكيل املخول لعمل ذلك او شخص مخول لذلك‬ RG 0 - Exempt .‫دامئا افصل الدائره الكهربائيه قبل تركيب او صيانه الجهاز‬ No risk IEC/EN 62471 Exempt IEC/TR 62778, RG2-RG1,C 0.4m IEC/TR 62778, RG1-RG0,C 1.6m *worst case scenario Rev D | 10-2023 www.schreder.com...