Installation
5 Commissioning
DANGER
Injuries due to electric shock
1.
Disconnect the mains plug before opening.
2.
Never touch live parts.
The device contains components that are sensitive to electrostatic discharges. Always
take the usual protective measures when handling the device.
5.1 Open the cover
1.
Loosen the cover screws and open the cover.
5.2 Configure downstream
5.2.1 Input attenuator (X1)
The attenuation can be adjusted via a PAD in 1 dB steps.
1.
Set the damping (PAD) according to the following table.
5.2.2 Cable simulator (X2)
The cable simulator can be adjusted via a PAD in 1 dB steps.
1.
Set the cable simulator (PAD) according to the level plan.
PAD Attenuator
(dB)
2
4
6
8
10
Cable simulator
258...1218 MHz
(dB)
1.5
3
4.5
6
8