6.
A distance of at least 30 cm between the short side of the radiant heater and the contiguous
walls is necessary, the distance beween the front-side and any surface must be 80 cm and at
least 6 cm must be between the heater and the back assembly surface. If necessary, please take
further protective measures as per the local re protections rules.
7.
No socket may be situated above the radiant heater and, additionally to that, there must not
be a socket in up to 10 cm next to the heater.
8.
Cords must never get in contact with the radiant heater.
9.
Recommended operating temperature: In ordert o make sure that your radiant heater is
e ectively operated and that energy is saved, do only switch on the heater when the ambient
temperatur is between 10 °C and 20°C.
10
. Please see the following picture. The graphics show how to mount the radiant heater on
ceilings as well as on walls, all minimum distances inclusive. The radiant heater must be moun-
ted in a height of at least 210 cm.
11.
Please ensure that a space of at least 80 cm is left between the long sides of he mounted
devices. If the devices are mounted in a way that the heating surfaces in front of each other the
distance between them must be at least 300 cm.
6.1 Minimum Distances
The indicated dimensions are calculated as minimum distances and can be di erent to the local
building and re protection regulations. The latter must urgently be kept to.
The pictured mounting surfaces must at least correspond to re protection classi cation A2.
Please note: If the radiant heater is mounted on the ceiling it is in conformity with the IP pro-
tection classi cation 4 (IP-X4), if it is mounted on a wall it is in conformity with the IP protection
classi cation 0 (IP-X0).