5.2 Connection with the mains
Connect the device to the mains with the CEE plug. The earth has to be connected! If the device will be
directly connected with the local power supply network, a disconnection switch with a minimum opening of 3
mm at every pole has to be included in the permanent electrical installation.
5.3 Outputs
Output is via six safety sockets and one 32A three-phase output socket.
Connect your loads via the output-sockets. The maximum load per channel is 3,680 W. Please note that the
maximum current must never be exceeded.
6. OPERATION
The device includes a multimeter for measuring current, voltage and frequency.
8888
I current display
A
8888
I current display
B
8888
I current display
C
8888
Voltage display
8888
Frequency display
Operating button:
Button
Function
Switch display between phase L1, L2 and L
Measuring current
In the first three lines, the values for the current phases A, B and C are indicated.
Measuring voltage
In the fourth line, the voltage of the set phase or line voltage is indicated. Use the button ⊳ to switch
between the phase voltages U
of the respective phases (L1, L2, L3) light up.
Measuring frequency
In the lower line, the measured frequency value is indicated.
7. CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tightly connected and must not
be corroded.
A
DIGITAL
MULTIMETER
A
Voltage
view key
A
Up
L1
Down
L2
L3
Set key
SET
Hz
, U
and U
as well as the line voltages U
A
B
C
15/16
, U
and U
The indicator LEDs
AB
BC
CA.
00145638, Version 1.0

Werbung

loading

Diese Anleitung auch für:

30248401