TROUBLESHOOTING
Low sensitivity of detection or the floodlight does not work:
Check if there are any obstacles in front of the device.
Check if the detection range is not exceeded.
Check if the device is mounted at an appropriate height.
Check if the brightness settings are consistent with the ambient
light.
When the environment temperature is similar to human body
temperature then detection sensitivity may slightly decrease.
The light does not turn off:
Check if there is constant motion within the detection range.
Check if the time is not set to the maximum.
EN
14
SPECIFICATION
URZ3484
24 pcs
Light source
SMD2835
Power
20 W
Color temperature
6500 K
Luminous flux
up to 1600 lm
Efficiency
80 lm/W
Power factor
Beam angle
CRI
Protection class
Protection rating
Working temperature
Lifespan
Power supply
Motion sensor
Light control
Range of activity time
setting
Detection range
Detection angle
Working temperature
Allowed air humidity
Installation height
Speed range of the
detected object
Protection rating
15
URZ3490
URZ3491
12 pcs
24 pcs
SMD2835
SMD2835
10 W
20 W
3000 K
up to 750 lm
up to 1500 lm
75 lm/W
0,9
120°
>80
I
IP65
-20°C ~ +40°C
20 000 h
220 - 240 V; 50 - 60 Hz
< 10-2000 LUX
10 s. - 7 min.
2 - 10 m
120°
-20 ~ +40°C
<93% RH
1.8 - 2.5 m
0.6 - 1.5 m/s
IP44