 The inlet of the compressed air I to the pneumatic motor is provided with a G1/4" thread. If
a fast clutch is used, make sure it is adequate to the pressure of the system.
Warning: If the compressed air valve is open the motor will start as soon as it has been
connected to the compressed air system.
First start with a new motor
Before starting the pump it is necessary to free the motor from protective grease which is ap-
plied during assembly; therefore carry out the following operations:
 Take off the elastic stop ring of the silencer.
 Take silencer out of its seat.
 Cover air exhaust hole with a strong cloth to avoid any residues carried by the compressed
air hitting the user.
 Let the vacuum pump work for about 20-30 seconds.
 The sound level reached without the silencer requires the use of ear protection.
 At the end of the operation put the silencer back on and fasten it with the stop ring.
Oil delivery
If all operations previously described are properly carried out and the compressed air valve is
open, to start oil delivery it is sufficient to press the lever on the handle of the delivery gun P.
If the lever is released the pneumatic pump stops automatically.
Warning: the delivery pipe is constantly under pressure.
Transport
 The pump is ready for use and is packed in such a way that none of its components can be
damaged during transportation.
 The packaging must not be discarded into the environment.
 To store or transport a new pump does not require any special care nor does it involve any
risks.
 If, after use, it is necessary to store, transport or dispose of the pump, the upper part of the
pumping system must be emptied by tipping it over and the lower part must be emptied by
lifting manually the bottom valve ball in order to avoid accidental leakage during move-
ment.
 During this operation smoking is prohibited, the use of protective gloves is advised. Do not
operate near naked flames.
The oil must be poured into a suitable container and disposed of in compliance with current
legislation.
Maintenance
 Change air exhaust filter when it clogs up, or after a maximum of 12 months.
 Check that there is no water trapped in the compressed air pipes of the system.
 Check all armatures for leakage and check the pipes and hoses for damages.
Operating problems, solutions
Insufficient delivery
If the problem continues consult an approved repair centre
44 1741 001 DE-H
TecPump DP x6
Check that there is no air in the oil distribution system
( this problem may occur when drum is changed).
Check that pressure is not lower than 4 bar.
Check filters during suction and delivery phase as well as the
pneumatic engine air silencer/ muffler