their flash point. Use in areas with explosion hazards is not permitted. In such cases, there is
a danger of explosion!
 Once the compressed air has been connected, the delivery gun can be started only when it
is sure that the oil flow is directed towards a suitable container.
Warning: Do not direct the jet towards people or objects, directing the jet against live
electrical control panels or electrical components could cause electrocution.
 Always put away the delivery gun P properly so that it cannot be started accidentally.
 Always switch off the compressed air feed after use. In the case of breakage of compo-
nents or pipes, oil could be discharged into the environment .
 To avoid compromising the safety of the user and the validity of the guarantee do not mod-
ify any component of the pneumatic pump.
 Repairs must be carried out using original parts only.
For safety reasons the user must only carry out routine maintenance (filter and silencer
replacement or cleaning,); it is necessary to consult an approved assistance centre for repairs
or replacement of components.
Warning: Disconnect the compressed-air-connection when sarting any kind of work on the
pump!
 In the case of scrapping, the appliance must be carefully emptied of the oil. (See chapter
"Transport")
 In exceptional cases, the components of this device may contain hazardous substances. In
accordance with the requirements of the European REACH regulation, we provide current
information on this on our homepage, in the download section.
Application of the pump to the oil drum
To apply pump to the drum it is necessary to use the appropriate ring nut G (thread 2" BSP)
and follow the instructions:
 Screw ring nut G to the drum.
 Unscrew the upper part of ring nut G1 until the inside conic insert G2 opens up enough to
insert the pumping system stem.
 Insert the pumping system stem in the ring nut G.
 If a filter or a bottom fitting is not applied to the pump, a space of about 15 mm must be
left between the bottom of the drum and the draining hole.
 Screw the upper part of the ring nut back on until pump is secured.
Connecting the delivery pipe
To protect the components from impermissibly high pressures, an overflow valve (safety
valve) should be installed.
 Use a ½" or ¾" pipe of very good quality which conform with DIN-SAE regulations, make
sure it is suitable to the pressure and to the liquid to be pumped.
 Connect one end of the pipe T to the outlet fitting R (Thread G ½ or ¾"spheric) of the pneu-
matic pump.
 Connect the other end of pipe with delivery gun P (supplied on request as an accessory).
Pneumatic connection
 Make sure that the delivery pipe is connected and the delivery gun is switched off .
 Find a compressed air outlet where the following components are installed:
Filter and steam trap.
­
Air lubricator.
­
Pressure reducing valve N to adjust the pressure max 8 bar.
­
Fast locking tap of compressed air to be used in the case of problems or emergency.
­