ATTENTION!
This charger can only charge the following
batteries: PAP 20 A1/PAP 20 A2/PAP 20
A3/PAP 20 B1/PAP 20 B3/PAPS 204 A1/
PAPS 208 A1.
A current list of battery compatibility can be
found at www.Lidl.de/Akku.

Before use

Router bit set

Original accessories included in delivery
For profiling
Roundover bit Ø 22 mm / R 6.3 mm
Ogee bit Ø 25 mm / R 4 mm
Cove bit Ø 22 mm / R 6.3 mm
V-groove bit Ø 12.7 mm / angle 90°
For joining
Straight bit Ø 6 mm
Straight bit Ø 12 mm

Inserting a router bit

Press the spindle locking button
down. The spindle lock must enter into the shaft.
Undo the union nut
wise with the open-ended spanner
Release the spindle locking button
Now insert the router bit.
This must be inserted to a depth of at least
20 mm.
Press the spindle locking button
down. The spindle lock must enter into the shaft.
Tighten the union nut
spanner
.
Release the spindle locking button
8
GB │ IE
and hold it
by turning it anticlock-
.
.
and hold it
using the open-ended
.
Connecting the extraction nozzle to
the routing module
Fit the extraction nozzle
provided for the extraction nozzle
sure that the projection on the extraction
nozzle
rests in the notch of the routing
module, then tighten the locking screw
the extraction nozzle
tion nozzle
, follow the steps in reverse order.
Attach an approved dust and sawdust extractor
to the extraction nozzle
Connecting the extraction nozzle to
the edge routing module
Fit the extraction nozzle
the edge routing module
Secure the extraction nozzle
locking screw
.
To remove the extraction nozzle
steps in reverse order.
Attach an approved dust and sawdust extractor
to the extraction nozzle

Changing the collet chuck

NOTE
All of the router bits in the supplied router bit
set have an 8 mm shank.
Use the pre-installed collet chuck
with these bits. When using router bits with
a 6 mm shank, replace the collet chuck as
described below.
Press the spindle locking button
down. The spindle lock must enter into the shaft.
Undo the union nut
open-ended spanner
(8 mm) can be removed.
onto the hole
. Make
on
. To remove the extrac-
.
into the recess on
.
using the
, follow the
.
(8 mm)
and hold it
anticlockwise with the
until the collet chuck
PMFAP 20-Li A1