Herunterladen Inhalt Inhalt Diese Seite drucken

HEIDENHAIN GAGE-CHEK 2000 Installationsanleitung Seite 24

Vorschau ausblenden Andere Handbücher für GAGE-CHEK 2000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.6
Wiring switching inputs and outputs
Depending on the peripherals to be
connected, the connection work may need to
be carried out by an electrical specialist.
Example: Safety Extra Low Voltage (SELV)
exceeded
Further information:
Page 20
The product fulfills the requirements of
standard IEC 61010-1 only if the power to
the peripheral devices is supplied from a
secondary circuit with current limitation as per
IEC 61010-1
3rd Ed.
limitation as per IEC 60950-1
2.5 or from a Class 2 secondary circuit as
specified in UL1310.
In place of IEC 61010-1
corresponding sections of standards DIN EN
61010-1, EN 61010-1, UL 61010-1 and CAN/
CSA-C22.2 No. 61010-1 can be used, and, in
place of IEC 60950-1
corresponding sections of standards DIN EN
60950-1, EN 60950-1, UL 60950-1, CAN/CSA-
C22.2 No. 60950-1 can be applied.
Wire switching inputs and outputs in accordance with
the pin layout
Further information:
"X104", Page 209
Further information:
"X105", Page 209
Further information:
"X106", Page 210
"X113", Page 210
Further information:
Remove and save the dust protection cap
Route the cables depending on the mounting variant
"Assembly of the product", Page 23
Further information:
Connect the connecting cables of the peripherals
tightly to their connectors
Further information:
"Device overview", Page 25
If the cable connectors include mounting screws, do
not overtighten them
The digital or analog inputs and outputs must
be assigned in the device settings of the
respective switching function.
5.7
Connecting input devices
Comply with the pin layout
"USB", Page 208
Further information:
Remove and save the dust protection cap
Route the cables based on the mounting variant
Further information:
"Assembly of the product", Page 23
Connect USB mouse or USB keyboard to USB Type-A
port (X32). Make sure the USB cable connector is fully
inserted
"Device overview", Page 25
Further information:
26
"Personnel qualification",
, Section 9.4 or with power
, Section
2nd Ed.
, Section 9.4, the
3rd Ed.
, Section 2.5, the
2nd Ed.
5.8
Connecting a network peripheral
Comply with the pin layout
"RJ45", Page 211
Further information:
Remove and save the dust protection cap
Route the cables depending on the mounting variant
"Assembly of the product", Page 23
Further information:
Connect the network peripheral to Ethernet port X116
using a standard CAT.5 cable. The cable connector
must firmly engage in the port
Further information:
"Device overview", Page 25
5.9
Connecting the line voltage
WARNING
Risk of electric shock!
Improper grounding of electrical devices may result in
serious personal injury or death by electric shock.
Always use 3-wire power cables
Make sure the ground wire is correctly connected to
the ground of the building's electrical installations
WARNING
Fire hazard due to wrong power cable!
Use of a power cable that does not meet the
requirements of the mounting location may cause a fire
hazard.
Use only a power cable that meets at least the
national requirements of the respective country in
which the product is mounted
Comply with the pin layout
"X100", Page 208
Further information:
Connect the power connection to a 3-wire grounded
power outlet using a power cable that meets
requirements
Further information:
"Device overview", Page 25
HEIDENHAIN | GAGE-CHEK 2000 | Installationsanleitung | 06/2021