3. When the voltage converter is switched on, the converter's control lamp does not light up:
The voltage selection switch has not been set to 220V. The device fuse from the voltage
converter has been blown.
4. When switching on the 110V device the control lamp of the voltage converter extinguishes:
- The converter was overloaded. The device fuse from the voltage converter has been blown.
- Your 110V device may be defective.
5. Control lamp from the converter lights up, but 110V device does not work:
Your 110V device may be defective.

REPLACING FUSE

The device fuse is installed to protect the voltage transformer. If the voltage selector switch is
overloaded or adjusted incorrectly, the fuse will break.
The fuse may only be replaced with a fuse of the same specifications (glass fuse, 5x20mm, slow,
250V). The fuse holder is located on the front of the transducer (plastic housing) or on the back
(metal housings). Unscrew the fuse holder with a screwdriver or coin. Pull the fuse out of the holder
and replace it with the same fuse. Screw in the holder again.
If the fuse blows again after replacement, the cause should be corrected first before the fuse is
replaced again.