Problem
C Staples / Nails are
not fully inserted,
bend or protrude
D Tool repeatedly
misfires
E Staples
/
Nails
jammed
in
guide plate
F
No staples / nails
are transported
*For troubleshooting: refer to the information in the "Technical data" chapter in part 1 of the instruction manual!
**See Chapter: "Intended use" in Instruction manual part 1!
***For troubleshooting: read chapter: "Commissioning"!
****For troubleshooting: read chapter: "Maintenance"!
If necessary, contact our service staff, see last page.
Cause
Tappet worn or broken
Working pressure (flow
pressure) too low
Compressor output too
small
Hose diameter too
small
Piston sluggish because
lubrication insufficient
Working pressure (flow
pressure) too low
O-ring damaged
Hose diameter too
small
Insertion depth setting
incorrect (if available)
Magazine (item 04)
the
dirty
Staple / Nail strip
jammed and/or not
pushed all the way for-
wards
Tappet worn
Staple/Nail jammed
No staples / nails in the
magazine
Tappet does not retract
Staple / Nail slider
faulty
Magazine spring faulty
KLG / KNG / SNG / RNG / PNG
Remedy
Contact Schneider Druckluft GmbH or an
authorised service partner.
Increase working pressure (flow pressure)
Observe maximum working pressure
Use different output
*
rating
Use correct hose diameter
Lubricate device well via plug nipple
***
(item 01)
Increase working pressure (flow pressure)
Observe maximum working pressure
Contact Schneider Druckluft GmbH or an
authorised service partner.
Use correct hose diameter
Check and adjust insertion depth setting.
Clean magazine
****
(blow out)
Incorrect staples / nails used. Insert the
correct staples / nails
Contact Schneider Druckluft GmbH or an
authorised service partner.
Unlock the quick-release cover (item 12)
(if available) via the magazine and re-
move the staple or nail.
Insert the correct staples / nails
Increase working pressure (flow pressure)
Observe maximum working pressure
or contact Schneider Druckluft GmbH or
an authorised service partner.
Contact Schneider Druckluft GmbH or an
authorised service partner.
Change magazine spring or
Contact Schneider Druckluft GmbH or an
authorised service partner.