6.1 Mechanical connection of the module

Evenness of the
mounting surface
08.00 | LDN | Assembly and Operating Manual | de en | GAS360925

6 Assembly

WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
Before starting any work on the product: Switch off the power
l
supply and secure against restarting.
Make sure, that no residual energy remains in the system.
l
DANGER
Danger from voltage!
Touching live parts can be deadly.
Switch off the power supply before any assembly, adjustment
l
or maintenance work and secure against being switched back
on again.
Only qualified electricians my carry out electrical installation work.
l
Disconnect the converters from the power supply.
l
The intermediate circuit capacitors must be discharged.
l
Note the correct sequence for connecting cables (first the
l
grounding cable, then conductors).
DANGER
Danger to life due to strong magnetic fields even in a shut-
down state.
The secondary parts integrated in the product are high-performance
permanent magnets. Medical devices such as pacemakers or
hearing aids may be destroyed or cause malfunctions.
Keep a sufficient minimum distance to the secondary part if
l
you have a pacemaker or are wearing hearing aids or the like.
The values apply to the whole mounting surface to which the
product is mounted.
Edge length
< 100
> 100
Tab.: Requirements for evenness of the mounting surface (Dimensions in mm)
Permissible unevenness
< 0.02
< 0.05
Assembly