12.1 RECOGNISING AND REPAIRING OF MISTAKES

LIGHT
PROBLEM
INDICATOR
Abnormal voltage protection
Overload / Overheating
Watershortage
Lock protection
Pump does not run or
not running properly.
12.2 DISPLAY FAULT CODES
Code
E10
Impeller Blocking
E11
Overvoltage fault
E12
Inverter Board overheating
E13
Water shortage
E17
Pressure sensor fault
E18
Electricity fault
protection
Winding stator damaged
Ambient termperature is
protection
Fault
REASON
Input voltage
is abnormal
Pump overload has
occurred
Bad heat dissipation
Impeller got stuck
too high
Water shortage
Unable self-priming,
Automatic suction
is no longer possible
The impeller is
stuck or wedged
Bearing is broken
Code
A14
Low voltage
A15
High voltage
A16
Pump tacking
English 7
SOLUTION
Check whether the circuit voltage
is between 180V-260V. If not, install a
voltage stabilizer
Voltage is too low or too high. Adjust
the voltage according to the device
Check whether the cooling fan fell
off or got damaged
Open the pump and remove the debries
Replace the winding stator
Set the ambient temperature below
45°C
Check the water source
Check whether the water level is
lower than the foot valve
Check whether the suction exceed 8m
Check if the pump is filled
with water. If not, refill water into the
pump body
Check if the inlet pipe is sealed. Any
little leakage will seriously impact
suction
Check if the impeller is broken. If yes,
replace the impeller
Check that the shaft rotates and
remove rotates and remove any
deposits, by opening the pump if
necessary.
Replace the bearing
Warning