Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Approval And Conformity - Grohe BLUE PROFESSIONAL 31324DC1 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Technical data

Cooler/carbonator electrical data:
• Connection:
Wall socket with earth wire, protected
• Voltage supply:
• Max. power consumption:
• Type of protection:
• Relative air humidity:
• Refrigerant:
• Safety shut-off of pump:
Sanitary data:
• Cooler/carbonator cooled water capacity:
• System operating pressure:
• Flow rate at 0.3 MPa flow pressure:
• Ambient temperature:
• Temperature
– Cooler /carbonator water inlet:
– Cooled water temperature:
• Sound pressure level L
A (frestanding):
p
• Adjustable bypass, factory setting:
• Filter capacity at bypass setting 2
(Carbonate hardness 10 - 24 °KH):
• Water connection
– cooler/carbonator:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.

Approval and conformity

This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Refer to the installation dimensions on fold-out page I.
Electrical installation work must only be performed by a
qualified electrician.
Install cooler/carbonator, see fold-out page I, Fig. [1].
When transporting or installing the cooler/carbonator,
cooling fluid may have run into the lines. In order
to ensure that the cooling fluid has run back, the cooler/
carbonator may only be switched on following a pause
of 24 hours.
Note the enclosed technical product informations,
see fig. [2]!
Connect cooler/carbonator and filter cartridge, see fold-out
page I, Figs. [3] to [10].
via a 10 A fuse
230 V AC / 50 Hz
270 W
IP21
max. 75%
0.065 kg - R134a
approx. 4:30 min
1.4 l
max. 0.6 MPa
approx. 2 l/min
4 – 32 °C
max. 20 °C
approx. 5 – 10 °C
50 ± 4 dB
2
max. 600 liters
corresponds to max. 12 months
cold - blue
A
2
2,500 V
Open hot and cold water supply and check that
connections are watertight, see Fig. [11].
Connect plug-in connection between fitting and cooler/
carbonator, see Fig. [12].
Establish voltage supply via mains plug, see Fig. [13].
The display illuminates and the remaining filter capacity is
displayed in percent.
Connect CO
cylinder, see fold-out page II, Figs. [14] to [18].
2
Note: A 2 kg CO
cylinder (Prod. no: 40 423 000) can be
2
ordered at www.shop.grohe.com.
Do not operate the valve on the back of the cooler/
carbonator as otherwise CO
2
The fitting has a system-related run-on time of
approx. 1 second each time carbonated water is drawn.
The display in the handle illuminates blue.
®
If the Blue
handle is flashing red and E4 or E6 appears in
the display, the fitting and cooler/carbonator must be
synchronised as follows, see Fig. [19]:
• Press and hold the  and  buttons simultaneously until SE
flashes in the display.
• Press the  button until SE stops flashing.
• Release the  button, C- flashes in the display.
• Keep pressing the  or  button until H- flashes in the
display.
• Press the  button until H- stops flashing.
®
• Blue
handle synchronisation starts; HC appears in the
®
display and the Blue
handle lights up red.
®
• As soon as the Blue
handle lights up green, open the fitting
®
fully by turning the Blue
handle.
®
• As soon as the Blue
handle briefly flashes green, close the
®
fitting by turning the Blue
handle, HC flashes in the display.
• Confirm the setting by pressing the  button longer, HC
appears.
• Release the  button.
The remaining filter capacity is displayed.
Commissioning
Control, see fold-out page II, Fig. [19].
The buttons have the following functions:
 Filter replacement reset
 Filter size selection
 Carbonate hardness adjustment
Display, see Fig. [19].
In the inactive state, the remaining filter capacity is displayed
in percent.
Set the temperature of the cooled, carbonated water on
the cooler/carbonator, see Fig. [20].
Set the filter size, see Fig. [19] and [21].
 button for filter size selection:
• Press and hold  button once until the currently setted
value (e. g. F1) flashes in the display
• Press the  button and select the required value appears
- F1:
S
40 404 000
- F2:
M
40 430 000
- F3:
L
40 412 000
- F4:
S
40 404 001
- F5:
M
40 430 001
- F6:
L
40 412 001
- F7:
Mg
40 691 001
- F8:
Ac
40 547 001
will escape, see Fig. [15].
8

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis