Spezifikationen
epc8025RevEnergyActive
epc8025RevEnergyReactive
epc8025RevEnergyActiveResetta-
ble
epc8025RevEnergyReactiveReset-
table
epc8025ResidualCurrent
epc8025ResidualCurrentRMS
epc8025ResidualCurrentDC
epc8025LineSensorName
epc8025OVPIndex
epc8025OVPStatus
epc8025spActivePowerChan
epc8025spPowerIndex
epc8025spChanStatus
epc8025spAbsEnergyActive
epc8025spPowerActive
epc8025spCurrent
epc8025spVoltage
epc8025spFrequency
epc8025spPowerFactor
epc8025spPangle
epc8025spPowerApparent
epc8025spPowerReactive
epc8025spAbsEnergyReactive
epc8025spAbsEnergyActiveReset-
table
epc8025spAbsEnergyReactiveRe-
settable
epc8025spResetTime
epc8025spForwEnergyActive
epc8025spForwEnergyReactive
epc8025spForwEnergyActiveRe-
settable
epc8025spForwEnergyReacti-
veResettable
epc8025spRevEnergyActive
epc8025spRevEnergyReactive
Expert Power Control 8021/8025
Resettable Forward Reactive Energy counter.
.79.1.5.1.2.1.20.x
Reverse Active Energy counter.
.79.1.5.1.2.1.21.x
Reverse Reactive Energy counter.
.79.1.5.1.2.1.22.x
Resettable Reverse Active Energy counter.
.79.1.5.1.2.1.23.x
Resettable Reverse Reactive Energy counter.
.79.1.5.1.2.1.24.x
Actual Residual Current on Power Channel. According Type A IEC
60755. Only visible on models that support this feature.
.79.1.5.1.2.1.25.x
Actual Residual Current RMS on Power Channel. According Type B IEC
60755. Only visible on models that support this feature.
.79.1.5.1.2.1.26.x
Actual Residual Current DC on Power Channel. According Type B IEC
60755. Only visible on models that support this feature.
.79.1.5.1.2.1.100.x
A textual string containing name of a Line Sensor
.79.1.5.2.1.1.x
None
.79.1.5.2.1.2.x
shows the status of the built-in Overvoltage Protection
.79.1.5.5.1.0
Number of Single Port Power Channels. Value is zero on EPC 8220 se-
ries.
.79.1.5.5.2.1.1.x
Index of Single Port Power Channel entries. Indices 0-5 mean Ports A1
to A6, 6-11 are Ports B1 to B6.
.79.1.5.5.2.1.2.x
0 = data not active, 1 = data valid
.79.1.5.5.2.1.3.x
Absolute Active Energy counter.
.79.1.5.5.2.1.4.x
Active Power
.79.1.5.5.2.1.5.x
Actual Curent on Power Channel.
.79.1.5.5.2.1.6.x
Actual Voltage on Power Channel
.79.1.5.5.2.1.7.x
Frequency of Power Channel
.79.1.5.5.2.1.8.x
Power Factor of Channel between -1.0 and 1.00
.79.1.5.5.2.1.9.x
Phase Angle between Voltage and L Line Current between -180.0 and
180.0
.79.1.5.5.2.1.10.x
L Line Mean Apparent Power
.79.1.5.5.2.1.11.x
L Line Mean Reactive Power
.79.1.5.5.2.1.12.x
Absolute Reactive Energy counter.
.79.1.5.5.2.1.13.x
Resettable Absolute Active Energy counter. Writing '0' resets all resetta-
ble counter.
.79.1.5.5.2.1.14.x
Resettable Absolute Reactive Energy counter.
.79.1.5.5.2.1.15.x
Time in seconds since last Energy Counter reset.
.79.1.5.5.2.1.16.x
Forward Active Energy counter.
.79.1.5.5.2.1.17.x
Forward Reactive Energy counter.
.79.1.5.5.2.1.18.x
Resettable Forward Active Energy counter.
.79.1.5.5.2.1.19.x
Resettable Forward Reactive Energy counter.
.79.1.5.5.2.1.20.x
Reverse Active Energy counter.
.79.1.5.5.2.1.21.x
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Unsigned32
RO
Unsigned32
RO
Unsigned32
RO
OCTETS
RW
Integer32
RO
INTEGER
RO
Unsigned32
RO
Integer32
RO
Integer32
RO
Gauge32
RO
Integer32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Gauge32
RO
Gauge32
RW
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
© 2019 GUDE Systems GmbH
58