Spezifikationen
epc8021AbsEnergyReactiveReset-
table
epc8021ResetTime
epc8021ForwEnergyActive
epc8021ForwEnergyReactive
epc8021ForwEnergyActiveReset-
table
epc8021ForwEnergyReactiveRe-
settable
epc8021RevEnergyActive
epc8021RevEnergyReactive
epc8021RevEnergyActiveResetta-
ble
epc8021RevEnergyReactiveReset-
table
epc8021ResidualCurrent
epc8021ResidualCurrentRMS
epc8021ResidualCurrentDC
epc8021LineSensorName
epc8021OVPIndex
epc8021OVPStatus
epc8021SensorIndex
epc8021TempSensor
epc8021HygroSensor
epc8021InputSensor
epc8021AirPressure
epc8021DewPoint
epc8021DewPointDiff
epc8021ExtSensorName
4.5.2
Geräte MIB 8025
Es folgt eine Tabelle aller gerätespezifischen OID's die über SNMP angesprochen wer-
den können. Bei der numerischen OID Darstellung wurde der Präfix
"1.3.6.1.4.1.28507" zur Gude Enterprise OID aus Platzgründen bei jedem Eintrag in
der Tabelle weggelassen. Die komplette OID würde daher z.B.
"1.3.6.1.4.1.28507.79.1.1.1.1" lauten. Man unterscheidet in SNMP bei OID's zwischen
Tabellen und Skalaren. OID Skalare haben die Endung ".0" und spezifizieren nur einen
Wert. Bei SNMP Tabellen wird das "x" durch einen Index (1 oder größer) ersetzt, um
einen Wert aus der Tabelle zu adressieren.
Expert Power Control 8021/8025
ble counter.
.77.1.5.1.2.1.14.x
Resettable Absolute Reactive Energy counter.
.77.1.5.1.2.1.15.x
Time in seconds since last Energy Counter reset.
.77.1.5.1.2.1.16.x
Forward Active Energy counter.
.77.1.5.1.2.1.17.x
Forward Reactive Energy counter.
.77.1.5.1.2.1.18.x
Resettable Forward Active Energy counter.
.77.1.5.1.2.1.19.x
Resettable Forward Reactive Energy counter.
.77.1.5.1.2.1.20.x
Reverse Active Energy counter.
.77.1.5.1.2.1.21.x
Reverse Reactive Energy counter.
.77.1.5.1.2.1.22.x
Resettable Reverse Active Energy counter.
.77.1.5.1.2.1.23.x
Resettable Reverse Reactive Energy counter.
.77.1.5.1.2.1.24.x
Actual Residual Current on Power Channel. According Type A IEC
60755. Only visible on models that support this feature.
.77.1.5.1.2.1.25.x
Actual Residual Current RMS on Power Channel. According Type B IEC
60755. Only visible on models that support this feature.
.77.1.5.1.2.1.26.x
Actual Residual Current DC on Power Channel. According Type B IEC
60755. Only visible on models that support this feature.
.77.1.5.1.2.1.100.x
A textual string containing name of a Line Sensor
.77.1.5.2.1.1.x
None
.77.1.5.2.1.2.x
shows the status of the built-in Overvoltage Protection
.77.1.6.1.1.1.x
None
.77.1.6.1.1.2.x
actual temperature
.77.1.6.1.1.3.x
actual humidity
.77.1.6.1.1.4.x
logical state of input sensor
.77.1.6.1.1.5.x
actual air pressure
.77.1.6.1.1.6.x
dew point for actual temperature and humidity
.77.1.6.1.1.7.x
difference between dew point and actual temperature (Temp - De-
wPoint)
.77.1.6.1.1.32.x
A textual string containing name of a external Sensor
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Unsigned32
RO
Unsigned32
RO
Unsigned32
RO
OCTETS
RW
Integer32
RO
INTEGER
RO
Integer32
RO
Integer32
RO
Integer32
RO
INTEGER
RO
Integer32
RO
Integer32
RO
Integer32
RO
OCTETS
RW