Herunterladen Inhalt Inhalt Diese Seite drucken

Schneider Airsystems ZPM 97-15-2 W Originalbetriebsanleitung Seite 7

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
Table of contents - Part 1
1.1
General information ..................
1.2
Scope of delivery ......................
1.3
Conventional use ......................
1.4
Technical data ..........................
1.5
Components.............................
1.6
Maintenance.............................
1.7
Compressor inspections .............
1.8
EC Declaration of Conformity ......
The specified illustrations appear at the be-
ginning of the Operating Instructions.
1.1
General information
Observe the safety instructions!
1.4
Technical data
Suction capacity
Filling capacity
Voltage
Electric protection, delayed-action
Motor output
Max. operating speed
Compression final pressure
Switch-on pressure
Vessel capacity
Maximum permissible working overpressure of vessel
1
Oil quantity
L
Sound power level according to DIN EN ISO 3744 (RL 2000/
WA
14/EC)
L
Sound pressure level at distance of 4 m
PA4
Overall dimensions: width x depth x height
Weight
Max. number of switching cycles
Operation/Downtime ratio
Min. distance to wall
Ambient temperature
1.
Initial filling: mineral oil up to 10 °C. Under 10 °C, use fully synthetic oil.
1.5
Components
01
Compressor unit
02
Intake filter
Read the Instruction Manual!
Note: Read and memorise part 2 of the in-
3
struction manual!
Subject to technical modifications. Illustra-
3
tions may deviate from the original.
3
1.2
Scope of delivery
3
– Compressor with instruction manual
3
– Accessories pouch with oil dipstick
4
– Documents accompanying compressed air
vessel
4
1.3
Conventional use
4
The compressor is designed for generating
and storing compressed air only. Com-
pressed air is only suitable for compressed
air tools/devices/machines.
Any other type of use is considered contrary
to the intended use.
03
Oil dipstick
04
Oil drain screw
06
Pressure pipe
ZPM 97-15-2 W
87 l/min
50 l/min
230 V
6 A
0,55 kW
1420 rpm
15 bar
13 bar
2,4 l
16 bar
0,21 l
85 dB(A)
65 dB(A)
500 x 300 x 400 mm
21 kg
10 1/h
60:40 --
40 cm
5-35 °C
GB
I/3