TROUBLESHOOTING:
Error
Reason
code
Err 1
1. Engine failure
2. Counting sensor
failure
Err 2
1. The cable is wound
around the sprocket
2. Wrong cable winding
direction
Err 3
1. The door is not tied
2. Faulty position
sensor (U3)
3. The door is too light
4. The position of the
cable inside the
controller is incorrect
Err 4
The door must move at
a distance of more than
1.5 m
Err 5
1. Opening the door is
blocked
Solution
Return to the manufacturer's service centre for
repair
Return to the manufacturer's service centre for
repair
Open the panel. Press and hold the "↓" or "↑"
button for a few seconds to rotate the cable drum.
Once you have found the correct position, untangle
the cable from the sprocket. Press the "MENU"
button to clear the error. The door will perform a
functional test and then return to normal operation.
Press the "↓" button and pull the cable until it is
fully unwound and then it will wound in the correct
direction. When the cable is shortened to the
desired length, release the button. Use the "↑" or
"↓" buttons to adjust the length. After making the
adjustments, press the "MENU" button to clear the
error. The door will perform a functional test and
return to normal operation.
Tie the door. Wait 8 seconds, the door will perform
a functional test and then resume normal
operation.
Return to the manufacturer's service centre for
repair
Use a door weighing 300-1000 g. Wait 8 seconds
after installation. The door will then perform a
functional test and return to normal operation.
Open the front panel of the controller, position the
cable manually as shown on the PCB and wait 8
seconds. The door will then perform a functional
test and return to normal operation.
Press the "↑" button to shorten the path covered
by the door to match the entrance opening. Release
the "MENU" button to clear the error. The door will
perform a functional test and then resume normal
operation.
Check that the door is not blocked by obstacles.
After removing the obstacles, press the "MENU"
button to clear the error. The door will perform a
functional test and then resume normal operation.