2. Technical specifications

Model
Energy efficiency class
Rated capacity / rated current
Chosen capacity / current
Electrical connection
Min. required cable size
Hot water (l/min)
max. at ∆t = 28 K
max. at ∆t = 38 K
Rated volume
Rated pressure
Connecting type
Heating system
@ 15 °C:
Required specific water resistance
Specific electrical conductivity
Inlet temperature
Flow rate to switch on – max. flow rate
Pressure loss
Temperature range
Water connection
Weight (when filled with water)
VDE class of protection
Type of protection / safety
* ) The declaration complies with the EU regulation No 812/2013.
1) Mixed water
2) Flow rate limited to achieve optimum temperature rise
3) Without flow regulator

3. Dimensions

468 363
56
8.1 kW (36.6 A)
@ 220 V
@ 230 V
8.8 kW (38.3 A)
@ 240 V
9.6 kW (39.9 A)
170
Dimensions in mm
96
100
DEX 12 Next L
A *
)
8.8 kW..11.5 kW (38 A..50 A)
1/N/PE 220 V .. 230 V .. 240 V
10.0 mm
2
4.5
3.3
0.4 l
1.0 MPa (10 bar)
pressure-resistant / pressureless
Bare wire heating system IES
≥ 1300 Ωcm
≤ 77 mS/m
≤ 30 °C
1.5 l/min – 5.0
0.08 bar at 1.5 l/min
1.3 bar at 9.0 l/min
20 °C – 60 °C
G ½ inch
4.2 kg
I
IP25
239
27
10.5 kW (47.8 A)
11.5 kW (50.0 A)
12.5 kW (52.2 A)
5.9
1)
4.3
®
2)
3)