Herunterladen Inhalt Inhalt Diese Seite drucken

BOMANN DU 7607 G Bedienungsanleitung, Garantie Seite 45

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

 If you use your cooker hood in recirculation mode,
you must replace the activated carbon filter regu-
"Replacing the activated carbon filter"
larly (see
Cleaning the aluminum grease filter
WARNING: Risk of fire!
Grease residue in aluminum grease filter may ignite
at intense heat. Therefore, clean the grease filter
regularly!
Depending on model there are one or two grease
filters on the appliance. We recommend cleaning the
grease filter(s) every month:
 Remove the aluminum grease filter by sliding
back the lock in the handle recess, push the filter
down gently and pull out towards the front.
 Rinse the grease filter in a solution of hot water
and neutral detergent. Soak the filter in it.
 Then clean with a soft brush, rinse thoroughly with
hot water and allow drying.
 Alternatively, the grease filter can also be cleaned
in the dishwasher (up to 60°C). Slight discolora-
tion may occur. This does not affect the function
of the grease filter.
Replacing the activated carbon filter
The activated carbon filter prevents odors and must
depend on the use but be changed at least every six
months.
Order the carbon filter from your dealer or in our
online accessories shop, www.bomann-germany.de.
Use the reference number found under
Data".
 See
culation mode".
).
 Remove and dispose the old carbon filter.
Replacing the bulb
CAUTION:
Do NOT remove the LED lighting cover!
The bulb may only be replaced by an authorized
specialist in case of a defect.
WARNING:
 The LED light is very bright and can damage the
eyes. Never look directly into the LED light!
 Disconnect the appliance from the power supply
and allow the lamps to cool down before changing
the lamp. There is a risk of burns!
NOTE:
Order the lamps from your dealer or in our online
accessories shop www.bomann-germany.de.
Lamp data: LED max. 2 x 2.0 W, AC 110-240 V,
ILCOS D Code: DBR-2/30-H-64
 Remove the grease filter(s). Open the black pro-
tective box of the plug-in device and release the
plug connection.
 Carefully push the lamp out of the holder through
the housing.
 Replace defect LED module and connect the two
"Technical
ends of the plug-in device.
 Insert new lamp properly in the bulb holder.
45
"Installing the activated carbon filter for recir-

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis