Herunterladen Inhalt Inhalt Diese Seite drucken

SUHNER MACHINING BEW 6 Originalbetriebsanleitung Seite 25

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
The electronic or pneumatic proximity switches are set at
the factory.
c
onnection eletric
Blue
Brown
Black
Voltage
Output current
Output
c
onnection pneumatic
Connection P
Connection A
Feed pressure at P
Signal pressure range at A
2.2.3 p
neumatic aDVance
Attach air hoses (polyurethane hoses Di=4 mm, max.
pressure 7 bars, -35 to 60 °C ) to the installed pneumatic
connections.
For the quality of compressed air, see point 2.5!
w
ithout chip remoVal
Stroke «forward» (1). Stroke «back» (2).
All manuals and user guides at all-guides.com
w
ith chip remoVal
Stroke «forward» (1). Stroke «back» (2). Release brake (3).
p
rinciple of aDVance control
minus
plus
control pulse
12-24V DC
max. 200mA
PNP
black
yellow
0-8bar
0 - feed pressure
Machining unit (1). Oil brake (2). Inductive sensors (3). Ad-
justable speed regulation check valve (4). Bistable 4/2- or
5/2-way pulse valve (5). Main valve (6). Filter (7a). Pressure
regulator (7b). Oiler (7c). Mono-stable 4/2-way valve (only
with chip removal function) (8).
25

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis