5. Straighten the first 20 cm (7.9") of wire from the cold wire coil (8).
6. Insert the cold wire into the wire liner (2). While doing so hold the wire coil so that the wire (9) cannot "jump off" it.
7. Push the wire through the wire liner that is held stretched and slide it through the wire feed unit until the wire projects out at
the other end of the wire liner (2) by approx. 10 cm (3.94").
NOTE!
8
9
8. Close the cover (5) of the wire feed unit again.
9. Fold the knurled screw (4) down again and tighten it until the wire is secured against unintentional sliding out of the wire
liner.
10. Place the wire coil (8) on the holder. Continue to keep the wire coil tensioned, ensuring that it does not unwind.
11. Put the wire coil cover (6) back on and hand-tighten the knurled screw (7) again.