Herunterladen Inhalt Inhalt Diese Seite drucken

HERKULES HSE 5500/E5 Originalbetriebsanleitung Seite 26

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
10. Troubleshooting
Fault
Engine does not
start
Generator has too
little or no
voltage
The battery does
not charge up
Starter does not
turn
Anl_HSE_5500_E5_SPK7.indb 26
GB
Mögliche Ursache
Automatic oil cut-out has not respon-
ded
Spark plug fouled
No fuel
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air fi lter dirty
Poor contact to the battery
Battery defective
Defective fuse (Fig. 16a/16b)
Battery discharged
Battery not connected
- 26 -
Behebung
Check oil level, top up engine oil
Clean or replace spark plug (electro-
de spacing 0.6 mm)
Refuel / have the petrol cock checked
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the fi lter
Clean the contacts
Have the battery checked by an ex-
pert and replace it if necessary
Check the function of the equipment
using a diff erent battery; replace the
fuse
Charge the battery
Connect the battery
24.11.2020 11:49:55

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

41.525.63

Inhaltsverzeichnis