7.TROUBLE SHOOTING
1. FUNCTIONING TEMP.
5°C ≤ Ambient Temp. ≤ 35°C
When the ambient temp is lower or higher than the functioning temp, the dehumidifier
stops.
When 5°C ≤ Ambient temp. ≤ 16°C, the compressor automatically defrosts at intervals;
during defrosting, the compressor stops and the fan keeps running.

2. BEFORE CALLING FOR SERVICE

Before contacting professional service, please review the trouble shooting list that includes
common occurrences that are not the result of a defect in workmanship or materials.
Problem
Possible Cause
No power supply
Water Full Indication Flashes
Not working
Room temperature ˂ 5°C,or ˃
35 °C
Is the air filter clogged?
Bad
Is the intake duct or discharge
functioning
duct obstructed?
No air intake
Is the filter clogged?
Is the machine put in the plat
Loud
noise
place?
when
running
Is the filter clogged?
E2
Humidity sensor problem
Environmental humidity is below
LO
20%
Environmental humidity is above
HI
90%
Low temperature protection, the
CL
environmental temperature<5℃
High temperature protection, the
CH
environmental
35℃
8. DECOMMISSIONING
8.1 STORAGE
Long-term storage - If you will not be using the unit for an extended period of time (more
than a few weeks) it is best to clean the unit and dry it out completely. Please store the unit
per the following steps:
8. Press power button to switch off and unplug the unit.
9. Drain the remaining water from the unit.
10. Clean the filter and let the filter dry completely in a shaded area.
11. Collect the power cord at the water tank.
Solution
Connect to a functioning outlet and switch on
Drain water tank and reset it, or re-position the
water tank to right place
Self-Protection designed to protect the unit. Can
not work under such temperature
Clean the air filter as instructed
Remove the obstruction from the discharge duct
or intake duct.
Wash the filter
Put the machine on the plat ground
Wash the filter
Change a sensor
The dehumidifier shuts down for self- protection
temperature >