Herunterladen Inhalt Inhalt Diese Seite drucken

Programs For Measuring; Tip Dress Programs - Bosch Rexroth PSI 6 C 760-Serie Typspezifische Anleitung

Mittelfrequenz-umrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

R911336190 | PSI 6xCx.760.xx
Input "Weld Contactor Enable"
Output "Contactor open"
Contactor Enable" is set low, or a fault occurs, or E-Stop occurs, or a timeout
occurs.
A Timeout is defined as a period of time with no receipt of a "Start" signal. The
timeout is set for 60 seconds.
This input must be maintained high to allow Weld Contactor control logic to
function. The input may be used to open the Weld Contactor as necessary, i.e.
Tip Replacement. If this input is low during the receipt of a program start (with
ignition), an error message ("No weld contactor enable") is displayed.
This output is the inverted signal of input "Weld contactor feedback".
7.1.6

Programs for Measuring

The following programs will be preset with special values. They are preferably
used for measuring.
Programs for measuring
Tabelle 18:
Program
Electrode
239
1
240
1
241
2
242
2
243
3
244
3
245
4
246
4
7.1.7

Tip dress programs

7.1.8
Tip dress programs
The following programs are for tip dressing. After a schedule of these programs,
the actual count of the electrode assigned to the program will be reset.
By default, the following values are set:
Default values (tip dress programs)
Tabelle 19:
Program
Electrode
247
1
248
1
249
2
250
2
251
3
252
3
253
4
254
4
Weldtime [ms]
Current
100
On
100
On
100
On
100
On
100
On
100
On
100
On
100
On
Weldtime [ms]
Current
1
Off
1
Off
1
Off
1
Off
1
Off
1
Off
1
Off
1
Off
Bosch Rexroth AG
45/58
Features

Werbung

Inhaltsverzeichnis
loading