Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens simovert masterdrives Betriebsanleitung Seite 292

Wechselrichter (dc-ac) bauform einbaugerät
Vorschau ausblenden Andere Handbücher für simovert masterdrives:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical Data
Designation
Order number 6SE70...
Rated voltage
Input
Output
Rated frequency
Input
Output
Rated current
Input
Output
DC link voltage
Rated output
Aux. power supply
Aux. power supply
Pulse frequency [kHz]
Derating curve
Load class II acc. to EN60146-1-1:
Base load current
Overload current
Cycle time
Overload duration
Losses, cooling, power factor
Power factor
Converter cosϕU
Efficiency η
Pulse frequency 5 kHz
Dissipated losses
Pulse frequency 5 kHz
Cooling air required
Sound pressure level, dimensions, weights
Sound pressure level [dB(A)]
Type of construction
Dimensions
Width
Height
Depth
Weight
11-6
Downloaded from
www.Manualslib.com
33-2TG 0
[V]
[Hz]
[A]
312
262
[V]
[kVA]
172...217
[V]
DC 24 (20 -30) (3.0 A without options; more with options)
[V]
5.0 – 6.0
1)
< 0.92 ind. < 0.92 ind. < 0.92 ind.
0.98
[kW]
3.60
[m³/s]
0.41
82
G
[mm]
508
1450
460
[kg]
155
1) 6SE7035-1TJ50:
Overload duration 60 s
Cycle time
= 5 corresponds to MASTERDRIVES Motion Control
= 7 corresponds to MASTERDRIVES Motion Control Performance 2
manuals search engine
Value
33-7TG 0
35-1TJ 0
DC 510 to 650 (-15 % / +10 %)
3 AC 0 ... rated input voltage x 0.64
---
0 ... 400
367
503
308
423
= rated direct voltage
203...256
278...351
AC 230 ±15 % (for the fan)
5.0 – 6.0
5.0 – 6.0
0.91 x rated output current
1.6 x rated output current
300 s
30 s
0.98
0.98
4.50
5.20
0.41
0.46
82
79
G
J
508
800
1450
1400
460
551
155
250
Overload current only 1.36 x rated output current
300 s
Operating Instructions
06.2006
6SE7087-6KN50
Siemens AG
SIMOVERT MASTERDRIVES