Herunterladen Inhalt Inhalt Diese Seite drucken

Conrad VC-602 Bedienungsanleitung Seite 46

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Measurement tolerances
Statement of accuracy in ±(% of the reading + number of digits =
dgt(s) )
Accuracy for 1 year at a temperature of +23°C ±5K, at a relative
humidity of less than 70 %. The warm-up time is 1 minute
Operating
mode
DC
voltage
Max. input voltage in the 200 mV measurement range: 500 VDC or
350 VAC rms 15s max.
AC
voltage
Valid for a frequency range from 50 Hz to 500 Hz
AC current
Calibrateable
Resistance 200 Ohm
The voltage to an open-circuit being measured is 3 V max. in the 200 Ohm ran-
ge and 0.3 V max. in the remaining ranges
Diode test
Test current approx. 1 mA; Test voltage < 3 V
46
Downloaded from
www.Manualslib.com
Measurement
range
200 mV
20 V
1000 V
200 V
750 V
20 A
20 A
200 A
200 A
1000 A
1000 A
up to
up to
400 A/ max. 200Hz
more than 400 A/max. 100Hz
2 kOhm
20 kOhm
200 kOhm
2 MOhm
20 MOhm
2000 mV
manuals search engine
Accuracy
±(0.5%+3dgt)
±(0.5%+3dgt)
±(0.5%+3dgt)
±(1.5%+4dgts)
±(1.5%+4dgts)
±(2.5%+5dgts)
±(3.5%+5dgts)
±(1.5%+5dgts)
±(3.0%+5dgts)
±(2.0%+5dgts)
±(3.5%+5dgts)
40 A/max. 400Hz
±(2.0%+5dgts)
±(1.5%+2dgts)
Resolution
Frequency
0.1 mV
10 mV
1 V
0.1 V
1 V
0.01 A
50 to 60Hz
0,01 A
61 to 400Hz
0,1 A
50 to 60Hz
0,1 A
61 to 400Hz
1 A
50 to 60Hz
1 A
61 to 400Hz
0.1 Ohm
1 Ohm
10 Ohm
0.1 kOhm
1 kOhm
10 kOhm
1 mV

Quicklinks ausblenden: