Rod Assembly (PTFE rod antenna version)
Optional
Extension
PTFE paste is supplied with
PTFE rod antenna versions
(non-sanitary type).

Mounting instructions

• Simply screw SITRANS LR 200 into the process connection, and hand tighten.
• For pressure applications, it will be necessary to use PTFE paste (or other appropriate
thread-sealing compound) and tighten the process connection beyond hand tight.
The maximum torque is 40 N-m. (30 ft-lbs.)
Wiring
1
Power
WARNINGS:
dc terminals shall be supplied from an SELV
IEC-1010-1 Annex H.
All field wiring must have insulation suitable for rated voltages.
1.
Safety Extra Low Voltage
7ML19985QL81
Notes:
• Water or process fluids must not enter the
connecting threads: this could cause reflections
at the connection, which will appear as false
100 mm (4")
echoes.
• Apply a small amount of PTFE paste to the
antenna threads before threading the antenna
together, and tighten slowly. Ensure that the rod
50 mm (2")
sections mate securely with no gaps. Do not
apply too much PTFE paste or the parts will not
mate securely.
• Do not use wrenches or pliers. Hand tighten only
(except in pressure applications: see warning
above).