Herunterladen Diese Seite drucken

Siemens SIDOOR ATD400S Betriebsanleitung Seite 27

Bahnsteigtürantrieb
Vorschau ausblenden Andere Handbücher für SIDOOR ATD400S:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Note
AT system series power supplies are fitted with a molded safety plug in line with VDE. The plug forms part of the safety
chain of the AT system in the form of the "emergency stop" function. Permanently connected power supplies, including those
with a separate "emergency stop" switch, represent a modification of the certified device, and are not permissible.
The Sidoor door drives are "Equipment" and no "electrical installations in the proper sense". A type of equipment is subject
to other tests and guidelines than electrical equipment. Therefore - e.g. in the case of a possible insulation measurement of
an electrical installation carried out with a DC voltage of 500V - the equipment (door drive) must be disconnected from the
network, otherwise the built-in protective circuit of the power supply may be destroyed. A permanent connection must not be
made for the reasons stated, because it cannot be ensured that the device can be properly disconnected from the mains
when required.
2
Introduction
Platform screen door drive ATD400S
The platform screen door drive ATD400S is an "intelligent" door drive which drives platform screen doors. It is not suitable
for stand-alone operation. External commands are only accepted via the serial interface (machine-machine communication).
The control inputs (digital input signals) have no function. The ATD400S must therefore always be operated in conjunction
with an AT-EB.
The maintenance-free drive unit consists of a speed-controlled DC motor with non-self-locking gearing. The power is
transmitted by a toothed belt. The toothed belt passes over a deflector pulley, and can be fitted with two clutch holders. This
enables it to drive both single-sided and centrally-opening doors.
The platform screen door drive ATD400S can currently be used with the following components:
Component
Control unit
Motor M2
Motor M3
Motor M4
Transformers
Power supply unit
Emergency power
module
Note
Recommendation for optimal drive characteristics
An NT40 switch mode power supply is recommended for optimal door drive characteristics.
Operation of the door drive does not require limit switches. The door width and the OPEN and CLOSED positions are
determined automatically. A 7-segment display (H401) on the controller indicates the current operating states.
Operating instructions
These operating instructions are also installation instructions within the meaning of the Machinery Directive (2006/42/EC).
These operating instructions are valid for devices from firmware version 1.03.
Note
The illustrations in the instructions refer to Sidoor User Software version 1.11 and ATD400S version 1.03. The illustrations
for other versions may differ slightly.
Platform screen door drive ATD400S
A2B00101047-01, 08/2012
Version
Control unit for ATD400S
24 V motor, pinion right, for doors up to 120 kg
24 V motor, pinion left, for doors up to 120 kg
30 V motor, pinion right, for doors up to 180 kg
30 V motor, pinion left, for doors up to 180 kg
30V motor, pinion right, for doors up to 400kg
30V motor, pinion left, for doors up to 400kg
Mains transformer
NT40 Switched-Mode Power Supply
Emergency power module with connecting cable
Order No.
6FB1131-0BM10-3AT3
6FB1103-0AT11-5MA0
6FB1103-0AT10-5MA0
6FB1103-0AT11-4MB0
6FB1103-0AT10-4MB0
6FB1103-0AT11-3MC0
6FB1103-0AT10-3MC0
6FB1112-0AT20-2TR0
6FB1112-0AT20-3PS0
6FB1115-0AT10-4CP0