We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents to clean the device!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers. Should you need any spare parts, please use genuine parts.
The examination intervals for mobile electrical devices (German DGUV-V3) must be kept.
The operator has to make sure that the electrical devices are examined by an electrician before taking into
operation for the first time and after changes before taking into operation another time.
Electrical devices must only be taken into operation in a perfect condition and must be kept this way.
For keeping the perfect condition, electrical devices must repeatedly be approved in accordance with the
instructions given in the electro-technical guidelines.
A qualified electrician is responsible for the correct examinations.
Mobile electrical devices, extension cords with plugs, power cables with plugs and mobile cables with plugs
and permanent installation must be approved by an expert every three months.
Should you have further questions, please contact your dealer.

8. TECHNICAL SPECIFICATIONS

Power supply:
Power connection:
Power output:
Device fuse:
Transducer fuse:
Protection:
Voltage measurement:
Measuring impedance:
Measuring accuracy:
Frequency measurement:
Measuring accuracy:
Display:
Dimensions:
Weight:
All information is subject to change without prior notice. © 08.12.2021
Eurolite is a brand of Steinigke Showtechnic GmbH
D00136213.docx Version 1.0 Publ. 08/12/2021
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
380-400V AC, 50Hz
Mains input CEE 63A 5-pol (M) recessed mounting
8 x Safety contact (F), hinged lid mounting version fused
4 x CEE 16A 5-pol (F) recessed mounting fused
5 x 20 mm, T 2 A Fuse replaceable
3x, 5 x 20 mm, F 3 A Fuse replaceable
8 x circuit breaker C 16A 1-pol
4 x circuit breaker C 16A 3-pol
3 x fault-current circuit breaker (FI) Typ B 63A/0,03A 4-pol
100-380 V
>500 kohms
± (0.5 % + 2 counts)
45-65 Hz
± 1 Hz
Volts , amps , frequency
Width: 53.5 cm
Depth: 42 cm
Height: 40.5 cm
20.00 kg