CV - Table
Standard settings (D = Factory Default, PoM = Programmable with SPoM)
Table of configuration variables (CV table)
CV Description
7
Software version
8
Manufacturer ID
8
Decoder reset functions (see attachment 1)
(3 reset ranges available)
11 DCC Timeout
15 Programming lock (Key)
16 Programming lock (Lock)
29 DCC Configuration
Bit
Value
Bit 2
4
Bit 7
128
41 Switch address (High Byte)
42 Switch address (Low Byte)
50 Operation Mode
Bit
Value
Bit 0
1
Bit 7
128
51 Time automatic reverse right
52 Time automatic reverse left
119 shut off current
255 Decoder type
Attachment 1 – CV-Values at decoder reset
Resetwert
CV
11
29
Wert
2
132
OFF (Value 0)
digital operation only
loco address mode (deactivated)
OFF (Value 0)
with cut open function
standard switching direction
11
41
42
15
0
1
101 101
D
PoM Range Note
---
---
---
123
---
---
11
√
16
22
10
√
1...200 100ms per value
101
√
0...255 When CV15 = CV16, then the
101
√
1...199
132
√
ON (add all active values)
digital + analog operation
switch address mode
0
---
1...
2046
1
√
0
√
ON (add all active values)
no cut-open function
oposite switching direction
0
√
0...255 0 = off, 1...255 time base 1sec
0
√
0...255 0 = off, 1...255 time base 1sec
4
√
1...10
244
---
---
16
16
50
0
read only
read only
basic settings
Programming lock
Function Settings
decoder is programmable
bitwise programming
bitwise programming
ca. 10...100mA
read only
22
51
52 119
0
0
3
27