Safety Instructions

-
This device is not to be operated by people with reduced physical, sensorial or
mental capabilities or lack of experience and / or knowledge (including children).
-
This device is a technical tool to be used in closed areas or receptacles.
-
Protect your eyes and skin from UV light. In a very short period of time UV-C
radiation generates severe sunburn and painful conjunctivitis in the eyes.
-
The unintentional use of the device or a damaged housing may cause the spill of
dangerous UV-C radiation.
-
Devices showing evident damages must not be operated - please contact the
manufacturer in case!
EN
-
The UV lamp is not to be operated outside the flow reactor.
-
A long lasting interruption of the flow of water can lead
to a heating of the surface of the reactor.
-
Before opening the device, present operating and maintenance instructions should
be read.
-
Caution: Areas which can only be opened by using a tool
must to be considered as maintenance areas.
Unauthorized opening may be dangerous for the operator !

Assembly Instruction

General remarks
-
The PURION UV-C-disinfection plant is always the last step in the chain of water
treatment, since the distance to the sampling point should be as short as possible.
Espescially water filters provide perfect conditions for the grow of bacterias.
The disinfected water would become infected again if it runs through the fresh-
water circulation after the UV-C-plant. Pressure increasing devices should be
installed before the UV-C-plants.
-
Every PURION UV-C-lamp [12] has a decreasing UV-C power over operational time.
The manufacturer guarentees, that the UV plant has 60% of the initial UV-C-power
after 10.000 hours of operation.
The design of the PURION UV plants is always done according to this 60% value of
power and a transmission of 90 %T1cm.
With more than 10.000 hours of operation the lamp will still work but will not pro-
vide sufficient UV-C power for an optimal result.
-
Make sure that the reactor does not contain water during the frost period.