Recommended installation locations
The following suggestions are intended to help you with the placement and installation of your CO alarm.
Place out of the reach of children. Under no circumstance should children be allowed to handle the CO alarm.
Install in a bedroom or hallway located close to the sleeping area. Take special care to verify the alarm can be heard
in sleeping areas.
It is recommended that a CO alarm be installed on each level of a multilevel home.
Locate 1~3 meter (3.3~10feet) away from all fuel burning appliances.
Placing at eye level allows for optimum monitoring of the red and green indicator lights.
Ensure that all vents of the unit are unobstructed.
Do not install in dead air spaces such as peaks of vaulted ceilings, or gabled roofs.
Do not install in turbulent air from ceiling fans.
Do not place near fresh air vents or close to doors and windows that open to the outside.
Keep the CO alarm away from excessively dusty, dirty, or greasy areas such as kitchens, garages, and furnace rooms.
Dust, grease, and household chemicals can affect the sensor.
Keep out of damp and humid areas such as the bathroom.
Avoid spraying aerosols near the CO alarm.
Do not install in areas where the temperature is below -10°C or hotter than 45°C.
Do not place behind curtains or furniture. CO must be able to reach the sensor for the unit to accurately detect CO.
2.

PRODUCT OVERVIEW

2.1
FAULT indicator
The FAULT indicator (yellow LED) is used to indicate fault or warning status of the CO alarm.
2.2
POWER indicator
The POWER indicator (green LED) is used to indicate power status of the CO alarm. The POWER indicator will flash
every 40 seconds.
2.3
ALARM indicator
The ALARM indicator (red LED) is used to indicate alarm status of the CO alarm.
2.4
TEST/SILENCE button
The TEST/SILECNE button is used to test the unit. Press and hold to enable TEST function.
2.5
Alarm sounder
The alarm sounder is used to send out CO alarm warning and fault warning information.
2.6
LCD screen
Indicates CO concentration and alarm status.
If CO concentration overruns 20PPM, the function of temperature display will be disable.
- 2 -