• For any two separate electric animal fences, each supplied from a separate energizer
independently timed, the distance between the wires of the two electric animal
fences shall be at least 2.5m. If this gap is to be closed, this shall be effected by means
of electrically non-conductive material or an isolated metal barrier.
• Barbed wire or razor wire shall not be electrified by an energizer.
• A non-electrified fence incorporating barbed wire or razor wire may be used to
support one or more off-set electrified wires of an electric animal fence. The
supporting devices for the electrified wires shall be constructed so as to ensure that
these wires are positioned at a minimum distance of 150 mm from the vertical plane
of the non-electrified wires. The barbed wire and razor wire shall be earthed at
regular intervals.
• Follow the installation instructions regarding earthing.
• A distance of at least 10 m shall be maintained between the energizer earth electrode
and any other earthing system connected parts such as the power supply system
protective earth or the telecommunication system earth.
• Connecting leads that are run inside buildings shall be effectively insulated from the
earthed structural parts of the building. This may be achieved by using insulated high
voltage cable.
• Connecting leads that are run underground shall be run in conduit of insulating
material or else insulated high voltage lead-out cable shall be used. Care must be
taken to avoid damage to the connecting leads due to the effects of animal hooves or
tractor wheels sinking into the ground.
• Connecting leads shall not be installed in the same conduit as the mains supply
wiring, communication cables or data cables.
• Connecting leads and electric animal fence wires shall not cross above overhead
power or communication lines.
• Crossings with overhead power lines shall be avoided wherever possible. If such a
crossing cannot be avoided it shall be made underneath the power line and as nearly
as possible at right angles to it.
• If connecting leads and electric animal fence wires are installed near an overhead
power line, the clearances shall not be less than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Less than or equal to 1 000
Greater than 1 000 and less than or equal to 33 000
Greater than 33 000
• If connecting leads and electric animal fence wires are installed near an overhead
power line, their height above the ground shall not exceed 3 m.
This height applies either side of the orthogonal projection of the outermost
conductors of the power line on the ground surface, for a distance of:
- 2 m for power lines operating at a nominal voltage not exceeding 1 000 V;
- 15 m for power lines operating at a nominal voltage exceeding 1 000 V.
6
Power line Voltage V
Gallagher Solar Fence Energizer User Manual
Clearance m
3
4
8