STATEMENT OF USE
Power tool with 0.498 shank for use with chisel
and various 0.498 shank accessories
No other use permitted.
For professional use only.
DATA
See page 3.
AIR SUPPLY REQUIREMENTS
The tool is designed for a working
pressure of 6.3 bar (90 psig). The
compressed air must be clean. The
installation of a filter is recommended.
For maximum efficiency and
performance, comply with the
specification of the air hose (antistatic
hose). (Refer to figure 2 for compressed
air connection).
LUBRICATION
● Use an air line lubricator with SAE #10 oil,
adjusted to two drops per minute. If an air line
lubricator cannot be used, add air motor oil to
the inlet once a day.
OPERATION
● To insert chisel, press loop on retainer aside,
push chisel into cylinder and release loop.
● Place cutting edge of chisel against workpiece
and press the trigger.
● Do not operate tool without chisel
in cylinder, or allow the chisel to be
driven out of cylinder. Internal damage
will result if piston is allowed to strike
cylinder wall.
Declaration of noise and vibration emission
See page 28.
Vibration levels.
Sound levels.
: Vibration levels.
a
, a
hd
h
K / K
= K
pA
WA
L
: Sound pressure level.
pA
L
: Sound power level.
WA
All values are current as of the date of this
publication. For the latest information please visit
www.desouttertools.com.
These declared values were obtained by
laboratory type testing in accordance with the
stated standards and are suitable for comparison
with the declared values of other tools tested
in accordance with the same standards. These
declared values are not adequate for use in risk
assessments and values measured in individual
work places may be higher.
The actual exposure values and risk of harm
experienced by an individual user are unique
and depend upon the way the user works,
the workpiece and the workstation design, as
well upon the exposure time and the physical
condition of the user.
We, Desoutter, cannot be held liable for the
consequences of using the declared values,
instead of values reflecting the actual exposure,
in an individual risk assessment in a work place
situation over which we have no control.
This tool may cause hand-arm vibration
syndrome if its use is not adequately managed.
An EU guide to managing hand-arm vibration
can be found at http://www.pneurop.eu/uploads/
documents/pdf/PN3-02-NV_Declaration_info_
sheet_0111.pdf
We recommend a programme of health
surveillance to detect early symptoms which
may relate to noise or vibration exposure, so that
management procedures can be modified to help
prevent future impairment.