Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Features; Terminal Connections - Finder 72.A1 Bedienungsanleitung

Schwimmerschalter
Vorschau ausblenden Andere Handbücher für 72.A1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING
!
POINTS WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT
Before any operation on the float remember to disconnect the power supply from the main power.
Check that the maximum load power does not exceed the float's electrical values.
In case of cable damage by the final user or installer, the float must be replaced.
Do not make any joint on the cable of the float switch, as immersion of such joints could cause short circuits
or electrical shocks.

TECHNICAL FEATURES

AC: Max 10 A (250 V) resistive load - 8 A (250 V) inductive load
Operating temperature: max. +50°C (+40°C ACS)
Wire gauge: 7 mm
Max working pressure: 10 BAR
Protection Grade: IP 68
ACTIVATION ANGLE: 30°

TERMINAL CONNECTIONS

The upstream circuit must protect the electric wires from the overcurrent.
WARNING
Lack of protection shall null and void the warrany in the event the float breaks.
• Emptying: (Fig.2) when black and brown wires are used, the circuit opens when float is down and closes when
the float is up. Note: the blue wire must be insulated
• Filling: (Fig.3) when brown and blue wires are used, the circuit closes when float is down and opens when the
float is up. Note: the black wire must be insulated
Fig.2 EMPTYING
LOAD
ENGLISH
LOAD
Fig.3 FILLING