Turn off the device.
Remove the drain plug
Connect the drain pipe safely and
tightly, making sure it is not bent and
there is no obstruction.
Place the end of the pipe over a drain or
bucket and let the water flow freely
from the device.
Do not immerse the end of the pipe in
water, otherwise an "airlock" could form
in the pipe.
Prevent water damage:
Since the underpressure of the condensation tank is high, you need to tilt
the drain pipe towards the ground. The angle of inclination should be greater
than 20 degrees.
Straighten the hose to avoid bending it.
6.1. CLEAN THE AIR FILTER (every two weeks)
Dust collects in the filter and obstructs the airflow. Restricted airflow reduces the
efficiency of the system and if it is blocked, the unit can be damaged.
The air filter should be cleaned regularly. The air filter is removable for easy cleaning.
Do not use the device without the air filter, otherwise the evaporator may become
clogged.
Press the POWER button to turn off the device and unplug it from the mains.
1.
Remove the filter from the device.
2.
Use a vacuum cleaner to easily remove coarse dust from the filter.
3.

6. CLEANING AND MAINTENANCE