Herunterladen Inhalt Inhalt Diese Seite drucken

Levenhuk ERMENRICH MW20 Benutzerhandbuch Seite 3

Feuchtigkeitssensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
Ermenrich MW20 Moisture Detector
EN
Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the
device only as specified in the user manual.
Getting started
Open the battery compartment cover and insert a 9V battery. Close the cover.
Press the POWER button to turn the device on/off.
Settings
To select the construction material, press the MODE button.
Press the HOLD button to hold the current measurement on the display, and then press it again to release the hold.
Press and hold the HOLD button to switch between °C and °F.
Using
Carefully press the test pins into the material whose moisture level you wish to measure. The level will be displayed as a percentage. The
following table shows the display indications for all possible moisture level readings in six modes.
Mode
Materials
1
Beech, Spruce, Larch, Birch, Cherry, Walnut, Oak, Pine, Maple, Ash-tree, Douglas fir
2
Cement screed, concrete, plaster
3
Anhydrite screed
4
Cement mortar
5
Lime mortar
6
Bricks
Calibration
Press the RESET button in the battery compartment to reset the calibration.
Charging
When the low battery icon appears on the screen, please replace the battery.
Specifications
Resolution
Measurement accuracy
Measuring range
Operating temperature range
Operating humidity
Auto-off
Protection class
Power supply
Dimensions
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Use the device only as specified in the user manual. Keep away from children. Do not try to disassemble the device on your own for any
reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact
and excessive mechanical force. Do not use the product in explosive environment, close to flammable materials. Store the device in a dry
cool place. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate
a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention
immediately.
Wood and Building Materials Measurement Mode Reference Table
0.1%
±2%
wood: 6...44%
building materials: 0.0...8.5%
0... +40°C (operating), -10...+50°C (storage) /
32...104°F (operating), 14...122°F (storage)
80 %RH
2 min.
IP20
1 9V battery
130x52x30mm / 5.1x2.0x1.1in
3
Measuring range
6...44%
1.4...7.4%
0.0...4.1%
0.8...5.1%
0.4...3.7%
0.0...8.5%

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ermenrich 81429

Inhaltsverzeichnis