RECOMMENDATION AND PRECAUTIONS FOR USE
1)Do not start two or more machine simultaneously. Turn on one at a time.
2)Warm the engine without connect any device for three minute about. If the generator supply
power to more than one device, be sure to connect one at a time. Many devices to switch on
require more than their rated voltage. Do not surpass the specified limit for every single power
point.
3)Be sure that every device has good condition before connecting to the generator. If a device
start to give signal of malfunctioning (working low or turning off suddenly), switch off the genera-
tor immediately. Disconnect the device and check it according to its malfunctioning signals. Is
the circuit surge set off the protection of the electric circuit, reduce the electric charge on the
circuit and wait few minute before restarting to operate. If the indication of the voltmeter indicates
a value too low or too high, switch off the machine and check the causes of the malfunctioning.
The generator can work when the voltmeter indicator shows 230! At 10% (50 Hz) on the control
panel.
4)Use of the direct current: do not use direct current 12V and alternating current in the same
time. The terminal of direct current can be used only to charge automatic batteries 12V. Using
automatic batteries with cords, be sure to disconnect the negative pole of the battery before
the charge. Do not mix the poles of the battery cords up or serious damages could occur to the
generator and/or to the battery.
5)During the connection of the generator to the domestic electric circuit, be sure that it is oper-
ated by qualified personnel. Wrong connections between the generator and the electric circuit
could provide damages to the generator or to the circuit till causing a fire.
Caution: if the generator must be connected to the electric line, be sure that the general switch
is off. Otherwise, the sudden return of the electric power could cause serious damages to the
generator or to the electric circuit till causing a fire.
STOP OF WORKING
1.Move on "OFF" position the switch of the generator
2.Move the fuel facet on "OFF" position
In case of electric starting rotate the starting key in "OFF" position (stop)
3.Rotate the fuel faucet in "S" position (close)
4.Slowly extract the recoil starter till the point of maximum resistance (that is till the phase of
compression) and leave the device in that position. This will avoid the rust formation on engine
firm.
ENGLISH