warning and the hazard symbols refer to procedure-specific risks. When these
symbols appear in the body of this manual or on warning labels, refer back
to these warnings again. Product-specific hazard symbols and warnings not
covered in this section may appear throughout the body of this manual where
applicable.
SKIN INJECTION HAZARD
High-pressure spray is able to inject toxins into the body and cause serious
bodily injury. In the event that injection occurs, get immediate surgical treat-
ment.
• Do not aim the gun at, or spray any person or animal.
• Keep hands and other body parts away from the discharge. For example, do
not try to stop leaks with any part of the body.
• Always use the nozzle tip guard. Do not spray without nozzle tip guard in
place.
• Use STORCH nozzle tips.
• Use caution when cleaning and changing nozzle tips. In the case where the
nozzle tip clogs while spraying, follow the Pressure Relief Procedure for tur-
ning off the unit and relieving the pressure before removing the nozzle tip to
clean.
• The system remains pressurised after having switched it off. Do not leave
energised or pressurised units unattended. Follow the Pressure Relief Proce-
dure when the equipment is unattended or not in use, and before servicing,
cleaning, or removing parts.
• Check hoses and parts for signs of damage. Replace any damaged hoses or
parts.
• This system is capable of producing 227 bar. Use STORCH replacement
parts or accessories that are rated a minimum of 227 bar.
• Always engage the trigger lock when not spraying. Verify the trigger lock is
functioning properly.
• Verify that all connections are secure before operating the unit.
• Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar
with the controls.

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite
or explode. Paint or solvent flowing through the equipment can cause static
sparking. To help prevent fire and explosion:
• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable
electric lamps, and plastic drop cloths (potential static sparking).
• Ground all equipment in the work area. See Grounding instructions.
• Never spray or flush solvent at high pressure.
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off
when flammable fumes are present.
• Use only grounded hoses.
• Hold gun firmly to side of grounded pail when triggering into pail. Do not use
pail liners unless they are anti-static or conductive.
• Stop operation immediately if static sparking occurs or you feel a shock. Do
not use equipment until you identify and correct the problem.
• Keep a working fire extinguisher in the work area.