Charging and Discharging Overload Protection and Recovery Time
In the charging and discharging overload protection mechanism, the relation
between overload current and protection time is as follows: An overload current 1.25
times of the rated current initiates a delay of 30s before starting protection; similarly,
1.5 times, 5s and 2 times, 1 s.
Overload recovery: automatic recovery after 1 minute.
Load Short Circuit and Recovery
Short-circuit automatic recovery time: 1st time, 5 s; 2nd time, 10 s; 3rd time, 15 s; 4th
time, 20 s; 5th time, 4 hours or automatic recovery the next day; or long press
to make the load resume output.
Installation Instructions and Precautions
1) The controller shall be installed securely, and its dimensions are as follows:
ECO-SC60A External dimensions:
1893x128x53.1(mm)
Installation dimensions: 180x92.2 (mm)
- 7 -