4.Installation Instruction
Attention:
Installation shall be done by qualified technician only.
Ensure power is OFF before all operations.
Pay attention to the accessories set when open the package.
There is at least 0.2mm distance between the lamp and the inflammable materials.
The power line can be fixed by terminal connector and need to make sure it is fixed tightly.
Make sure the power line get enough length to avoid any pull force of the line.
Required Tools: Electric Hand Drill, Screwdrivers, Ladder, etc.
Pre-configuration :
To achieve best performance, please take the following into consideration:
1)The default setting of the light is "Day & Light Mode", which can be activated any time.
2)Recommended mounting height of the light is 6ft to11-1/2 ft(1.8-3.5M). The detective
capability of the PIR sensor varies upon the installation height.
3)To avoid mistaken triggering,
a)the sensor should be kept away from heat sources such as barbecues, air conditioning,
and other outdoor lighting.
b)the installation should be positioned away from location of strong electromagnetic
interference.
c)the sensor should not be positioned towards reflective surfaces such as smooth white
walls, swimming pools, etc.
1. Surface mounted Directly
Suitable for No Previous Recessed Embedded Box.
StepⅠ: Drill two holes (4.8mm) in the wall/ceiling
and insert the anchor nuts into the newly drilled.
4.8mm
200mm
Anchor nuts
StepⅡ: Connect the "L" "N" and Earth wire
with terminal connectors. Check fixed tightly. Cut
the edge of the panel light along the dotted line and
pass the wires through the opening, ensure the
light fits tightly to the ceiling.
4
LED Panel Light Series
N: Neutral
L: Live
(Brown)
(Blue)
:Earth
(Yellow/
Green)