Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Repair; Notices; Spare Part Ordering Information; Technical Data - Sulzer COX ElectraFlow Dual Ultra Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17

9) MAINTENANCE AND REPAIR

Notices

All maintenance and repairs may only be
carried out by sites authorized by the manu-
facturer and exclusively by qualified and suit-
ably trained personnel (refer to the address
list at the back).
i
WARNING Risk of injury due to acci-
dental actuation of the dispenser and/
or opening of the device!
Never open the electric drive

If the device/battery have fallen on the ground, send

them to your local Sulzer Mixpac UK Ltd service partner
for testing/repair
NOTICE
Risk of damage due to incorrect mainte-
nance and cleaning!
Always keep the dispenser clean, remove hardened

material daily.
Never use any corrosive cleaning agents or sharp

objects for cleaning the surface of the device (do not
use products containing silicone).

Spare part ordering information

When ordering spare parts, please provide the following
information:
• Serial number as stated on dispenser type plate
• Device type
• Article description / spare part number, see
"3) Scope of delivery" on page 5
Instruction handbook ElectraFlow
Dual Ultra · Version 1.3 · 9.4.21

10) TECHNICAL DATA

Operating force
Power source
Charger/Charging Times
Dispensing speed
Noise emissions
Hand arm vibration
Operating temperature
Transport and storage
temperature
Relative air humidity
Weight
.

11) DISPOSAL

i
WARNING
damage caused by incorrect disposal of
the dispenser, dispensed material/car-
tridges/batteries
Never dispose of the dispenser, dispensed material,

cartridges or batteries with domestic waste
Dispose of the dispenser, dispensed material, car-

tridges and batteries in accordance with the legal regu-
lations in the country of use
11 of 12
5.0 kN
(7.5 kN max load at stall)
18 V Li-Ion battery pack
refer to battery charger
instruction handbook
20-230 mm/minute
< 80 db (A)
2
< 2.5 m/s
+5 °C to +40 °C
0 °C to +40 °C
30 % – 80 % RH
(non-condensing)
3.5 – 4.5 kg
(depending upon model,
no battery or cartridge)
Risk of environmental
EN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis