Settings required in the HEIDENHAIN control:
After mounting the QSY 155 D, permanent changes to the machine parameter list and possibly
entries in the motor table of the HEIDENHAIN control are required.
Further information can be found in the Technical Manual of the respective
HEIDENHAIN control.
If you have any questions, contact the machine tool builder or HEIDENHAIN.
1.
Press the EMERGENCY STOP button!
2. Switch on the main switch of the machine.
3. Do NOT confirm the "Power interrupted" message at the control!
4. Call the machine parameter list.
5. Call the motor table of the HEIDENHAIN control.
Select the motor according to the table below and, in the machine parameter "Type of motor"
(MP 2200.x), assign it to the axis of which you have replaced the motor.
Defective QSY 093 B
ID 331143-03, without brake
ID 331143-04, with brake
10
Replacement QSY 155 D
ID 339881-03, without brake
ID 339881-04, with brake
MP entry
QSY155 D
QSY155 D